Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhen Ci Yan Jiu ; 49(2): 155-163, 2024 Feb 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38413036

RESUMO

OBJECTIVES: To investigate the mechanism of electroacupuncture (EA) at "Neiguan" (PC6) in impro-ving myocardial electrical remodeling in rats with acute myocardial infarction (AMI) by enhancing transient outward potassium current. METHODS: A total of 30 male SD rats were randomly divided into control, model and EA groups, with 10 rats in each group. The AMI model was established by subcutaneous injection with isoprenaline (ISO, 85 mg/kg). EA was applied to left PC6 for 20 min, once daily for 5 days. Electrocardiogram (ECG) was recorded after treatment. TTC staining was used to observe myocardial necrosis. HE staining was used to observe the pathological morphology of myocardial tissue and measure the cross-sectional area of myocardium. Potassium ion-related genes in myocardial tissue were detected by RNA sequencing. The mRNA and protein expressions of Kchip2 and Kv4.2 in myocardial tissue were detected by real-time fluorescence quantitative PCR and Western blot, respectively. RESULTS: Compared with the control group, cardiomyocyte cross-sectional area in the model group was significantly increased (P<0.01), the ST segment was significantly elevated (P<0.01), and QT, QTc, QTd and QTcd were all significantly increased (P<0.05, P<0.01). After EA treatment, cardiomyocyte cross-sectional area was significantly decreased (P<0.01), the ST segment was significantly reduced (P<0.01), and the QT, QTc, QTcd and QTd were significantly decreased (P<0.01, P<0.05). RNA sequencing results showed that a total of 20 potassium ion-related genes co-expressed by the 3 groups were identified. Among them, Kchip2 expression was up-regulated most notablely in the EA group. Compared with the control group, the mRNA and protein expressions of Kchip2 and Kv4.2 in the myocardial tissue of the model group were significantly decreased (P<0.01, P<0.05), while those were increased in the EA group (P<0.01, P<0.05). CONCLUSIONS: EA may improve myocardial electrical remodeling in rats with myocardial infarction, which may be related to its functions in up-regulating the expressions of Kchip2 and Kv4.2.


Assuntos
Remodelamento Atrial , Eletroacupuntura , Infarto do Miocárdio , Isquemia Miocárdica , Ratos , Masculino , Animais , Isquemia Miocárdica/terapia , Ratos Sprague-Dawley , Pontos de Acupuntura , Miocárdio/metabolismo , Infarto do Miocárdio/genética , Infarto do Miocárdio/terapia , Potássio/metabolismo , RNA Mensageiro/metabolismo
2.
J Integr Med ; 21(1): 89-98, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36424268

RESUMO

OBJECTIVE: The study explores the effects of electroacupuncture (EA) at the governing vessel (GV) on proteomic changes in the hippocampus of rats with cognitive impairment. METHODS: Healthy male rats were randomly divided into 3 groups: sham, model and EA. Cognitive impairment was induced by left middle cerebral artery occlusion in the model and EA groups. Rats in the EA group were treated with EA at Shenting (GV24) and Baihui (GV20) for 7 d. Neurological deficit was scored using the Longa scale, the learning and memory ability was detected using the Morris water maze (MWM) test, and the proteomic profiling in the hippocampus was analyzed using protein-labeling technology based on the isobaric tag for relative and absolute quantitation (iTRAQ). The Western blot (WB) analysis was used to detect the proteins and validate the results of iTRAQ. RESULTS: Compared with the model group, the neurological deficit score was significantly reduced, and the escape latency in the MWM test was significantly shortened, while the number of platform crossings increased in the EA group. A total of 2872 proteins were identified by iTRAQ. Differentially expressed proteins (DEPs) were identified between different groups: 92 proteins were upregulated and 103 were downregulated in the model group compared with the sham group, while 142 proteins were upregulated and 126 were downregulated in the EA group compared with the model group. Most of the DEPs were involved in oxidative phosphorylation, glycolipid metabolism and synaptic transmission. Furthermore, we also verified 4 DEPs using WB technology. Although the WB results were not exactly the same as the iTRAQ results, the expression trends of the DEPs were consistent. The upregulation of heat-shock protein ß1 (Hspb1) was the highest in the EA group compared to the model group. CONCLUSION: EA can effect proteomic changes in the hippocampus of rats with cognitive impairment. Hspb1 may be involved in the molecular mechanism by which acupuncture improves cognitive impairment.


Assuntos
Disfunção Cognitiva , Eletroacupuntura , Ratos , Masculino , Animais , Ratos Sprague-Dawley , Proteômica , Disfunção Cognitiva/terapia , Hipocampo
3.
Zhen Ci Yan Jiu ; 41(1): 70-3, 2016 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-27141625

RESUMO

OBJECTIVE: To observe changes of skin temperature along the Governor Vessel (GV) after moxibustion stimulation. METHODS: A total of 36 healthy volunteer subjects were recruited in the present study. The skin temperature of Mingmen (GV 4), Dazhui (GV 14), Shenzhu (GV 12), Zhiyang (GV 9), Zhongshu (GV 7), Yaoyangguan (GV 3) regions and their bilateral control sites (1.5 cun lateral to GV 4) was detected by using a Thermo Tracer TH 9100. RESULTS: Following moxibustion stimulation of GV 4 region, a marked infrared radiant track along the central part of the back covering the GV was observed in the healthy volunteer subjects, and the skin temperature levels of both GV 4 and its bilateral control points were significantly increased (P < 0.001). The skin temperature of GV 4 was remarkably higher than those of both left and right control points (P < 0.001). After moxibustion stimulation, the average skin temperature levels of GV 9, GV 7, GV 4 and GV 3 were all up-regulated in comparison with pre-moxibustion (P < 0.01). CONCLUSION: Moxibustion stimulation of Mingmen (GV 4) can induce an infrared radiant track along the central part of the back covering the GV and raise skin temperature of acupoint areas of the GV.


Assuntos
Pontos de Acupuntura , Meridianos , Moxibustão , Temperatura Cutânea , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
4.
Zhen Ci Yan Jiu ; 40(4): 309-12, 2015 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-26502546

RESUMO

OBJECTIVE: To observe the effect of electroacupuncture (EA) stimulation at Zhongwan (CV 12) on the skin microcirculatory blood flow along the Conception Vessel (CV) in yin-deficiency constitution volunteers. METHODS: A total of 16 yin-deficiency constitution volunteers (9 woman and 6 men) from 200 students of Fujian University of Traditional Chinese Medicine finished a body constitution questionnaire and showed a yin-deficiency constitution. Skin microcirculatory blood perfusion units (MBPU) at Danzhong (CV 17), Xiawan (CV 10) , and Qihai (CV 6) of the CV were measured by using a Laser Doppler Flowmetry (Peri Flux 5000) in normal constitution, before and after EA stimulation of Zhongwan (CV 12) for 20 min. RESULTS: Under normal condition, the cutaneous MBPU values were significantly lower in the Qihai (CV 6) than in both Danzhong (CV 17) and Xiawan (CV 10) (P < 0.01). After EA stimulation of CV 12 for 20 min, the MBPU values were significantly decreased in the CV 17 and CV 6 acupoint regions compared with pre-stimulation (P < 0.05). No significant changes of skin MBPU were found in Xiawan (CV 10) after EA stimulation of CV 12 (P > 0.05). CONCLUSION: EA at Zhongwan (CV 12) can reduce the skin MBPU values of CV 6 and CV 17 of the Conception Vessel in yin-deficiency constitution volunteers.


Assuntos
Eletroacupuntura , Microcirculação , Pele/irrigação sanguínea , Deficiência da Energia Yin/terapia , Pontos de Acupuntura , Adulto , Feminino , Humanos , Masculino , Meridianos , Pessoa de Meia-Idade , Voluntários , Deficiência da Energia Yin/fisiopatologia , Adulto Jovem
5.
Zhen Ci Yan Jiu ; 40(2): 146-50, 2015 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-26054201

RESUMO

OBJECTIVE: To observe the effect of different-frequency-electroacupuncture (EA) and moxibustion stimulation on rabbits' arrhythmias. METHODS: Newzealand rabbits were randomly divided into arrhythmia model (n = 18), EA-3 Hz (n = 19), EA-20 Hz (n = 19), EA-100 Hz (n = 18) and moxibustion (n = 18) groups. The arrhythmia model was induced by intravenous injection of 25 µg/kg aconitine. EA (3 Hz, 20 Hz or 100 Hz, 3.5-4 V) or moxibustion was applied to bilateral "Neiguan" (PC 6) for 20 min and electrocardiogram (ECG) of the standard limb lead II was recorded by using a Biosignal Processing Instrument. The concentration of serum hypersensitive C reactive protein (hs-CRP) content was detected by using ELISA method. RESULTS: Following EA intervention, the duration of aconitine-induced arrhythmia was significantly shorter in both EA-20 Hz and EA-100 Hz groups than in the model group (P < 0.05, P < 0.01), and the serum hs-CRP level in the EA-20 Hz group was significantly lower than that of the model group ( P < 0.05). No significant changes were found in the duration of arrhythmia in both EA-3 Hz and moxibustion groups, and in the serum hs-CRP level in the EA-3 Hz, EA-100.Hz and the moxibustion groups (P > 0. 05). CONCLUSION: EA stimulation of PC 6 at 20 Hz and 100 Hz has an anti-arrhythmic effect in aconitine-induced arrhythmia rabbits.


Assuntos
Pontos de Acupuntura , Arritmias Cardíacas/terapia , Eletroacupuntura/métodos , Moxibustão , Animais , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/fisiopatologia , Proteína C-Reativa/metabolismo , Terapia Combinada , Eletroacupuntura/instrumentação , Eletrocardiografia , Humanos , Masculino , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...